2008 Lexus LX 570FACTORY OEM SERVICE PROCEDURE

Pattern Select Switch: Inspection

  1. REMOVE NO. 1 PATTERN SELECT SWITCH ASSEMBLY 
    1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance 

    STANDARD RESISTANCE SPECIFICATION

    Tester Connection Switch Condition Specified Condition
    4 (P) - 3 (E) Pattern select (PWR) switch on Below 1 Ω
    4 (P) - 3 (E) Pattern select (PWR) switch off 10 kΩ or higher
    2 (2ND) - 3 (E) Pattern select (2ND) switch continuously pressed Below 1 Ω
    2 (2ND) - 3 (E) Pattern select (2ND) switch released 10 kΩ or higher

    If the result is not as specified, replace the No. 1 pattern select switch assembly.

    Fig 1: Identifying Pattern Select Switch Connector Terminals
    G05760721Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.