2008 Lexus LX 570FACTORY OEM SERVICE PROCEDURE

Heated Oxygen Sensor: Installation

  1. INSTALL NO. 2 HEATED OXYGEN SENSOR (for Bank 1 Sensor 2) 
    1. Temporarily install the sensor to the exhaust pipe by hand.
      Fig 1: Installing No. 2 Heated Oxygen Sensor
      G05150061Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Using SST, tighten the sensor.

      SST 09224-00010 

      Torque: without SST 

      44 N*m (449 kgf*cm, 32 ft.*lbf) 

      with SST 

      40 N*m (408 kgf*cm, 30 ft.*lbf) 

      HINT:

      • Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). If using a torque wrench with a length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (See PRECAUTION ).
      • Make sure SST and the wrench are connected in a straight line.
    Fig 2: Tightening No. 2 Heated Oxygen Sensor
    G04943780Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2) 
    1. Temporarily install the sensor to the exhaust pipe by hand.
      Fig 3: Installing Heated Oxygen Sensor
      G05150061Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Using SST, tighten the sensor.

      SST 09224-00010 

      Torque: without SST 

      44 N*m (449 kgf*cm, 32 ft.*lbf) 

      with SST 

      40 N*m (408 kgf*cm, 30 ft.*lbf) 

      Fig 4: Tightening Heated Oxygen Sensor
      G04943780Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      HINT:

      • Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). If using a torque wrench with a length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (See PRECAUTION ).
      • Make sure SST and the wrench are connected in a straight line.
  3. INSTALL FRONT EXHAUST PIPE ASSEMBLY 
    1. Install the front exhaust pipe assembly (See INSTALLATION ).
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.