Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Inspection Procedure
- INSPECT ECM (+B, +B1 VOLTAGE)
- Turn the engine switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition +B (A5-6) - E1 (E4-7) 9 to 14 V +B1 (A5-5) - E1 (E4-7) 9 to 14 V OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG: Go to next step.
- CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
- Disconnect the E4 ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition E1 (E4-7) - Body ground Below 1 Ω - Reconnect the ECM connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step.
- INSPECT ECM (IGSW VOLTAGE)
- Turn the engine switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition IGSW (A5-17) - E1 (E4-7) 9 to 14 V OK: Go to step 6
NG: Go to next step.
- CHECK FUSE (IGN FUSE)
- Remove the IGN fuse from the cowl side junction block RH.
- Measure the resistance of the IGN fuse.
Standard resistance:
Below 1 Ω
- Reinstall the IGN fuse.
NG: REPLACE IGN FUSE
OK: Go to next step.
- INSPECT IGNITION RELAY NO. 2
- Remove the IG2 relay from the engine room R/B No. 2.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 3 - 5 10 kΩ or higher 3 - 5 Below 1 Ω (when battery voltage applied to terminals 1 and 2) NG: REPLACE IGNITION RELAY NO. 2
OK: GO TO
- INSPECT ECM (MREL VOLTAGE)
- Turn the engine switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition MREL (A5-13) - E1 (E4-7) 9 to 14 V NG: REPLACE ECM
- CHECK FUSE (EFI FUSE)
- Remove the EFI fuse from the engine room R/B No.2.
- Measure the resistance of the EFI fuse.
Standard resistance:
Below 1 Ω
- Reinstall the EFI fuse.
NG: REPLACE EFI FUSE
OK: Go to next step.
- INSPECT INTEGRATION RELAY (EFI MAIN RELAY)
- Remove the integration relay from the engine room J/B No. 2.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 2A-5 - 2A-8 10 kΩ or higher Below 1 Ω
(when battery voltage applied to terminals 2A-6 and 2A-7)NG: REPLACE INTEGRATION RELAY
OK: Go to next step.
- CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY- ECM, INTEGRATION RELAY - BODY GROUND)
- Check the harness and the connectors between the integration relay and the ECM.
- Remove the integration relay from the engine room J/B and R/B No. 2.
- Disconnect the A5 ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 2A-6-MREL (A5-13) Below 1 Ω Standard resistance (Check for short)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 2A-6 or MREL (A5-13) - Body ground 10 kΩ or higher - Check the harness and the connectors between the integration relay and body ground.
- Remove the integration relay from the engine room J/B and R/B No. 2.
- Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 2A-7 - Body ground Below 1 Ω NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: CHECK AND REPAIR HARNESS AND CONNECTOR (TERMINAL +B OF ECM - BATTERY POSITIVE TERMINAL)
- Check the harness and the connectors between the integration relay and the ECM.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.