2008 Lexus GX 470FACTORY OEM SERVICE PROCEDURE

Inspection Procedure

HINT:

  • This DTC chart is on the premise that the engine is cranked normally. If the engine is not cranked, proceed to the PROBLEM SYMPTOMS TABLE  (See .
  • Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
  1. READ VALUE OF TECHSTREAM (STARTER SIGNAL) 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch ON and turn the tester ON.
    3. Enter the following menus: Powertrain/Engine and ECT/Data List/All Data/Starter Signal.
    4. Confirm the starter signal status when the ignition switch is operated.

      OK 

      IGNITION SWITCH POSITION

      Ignition Switch Position STARTER SIG
      ON OFF
      Start ON

    OK: Go to step  5

    NG: Go to Next Step 

  2. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY 
    1. Move the shift lever to the P or N position.
    2. Disconnect the P1 Park/Neutral Position (PNP) switch connector.
    3. Measure the resistance of the PNP switch
      Fig 1: Inspecting Park/Neutral Position Switch Assembly
      G05264293Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard resistance 

      STANDARD RESISTANCE

      Shift Position Tester Connection Specified Condition
      P 2 - 6, 4 - 5 Below 1 Ω
      R 1 - 2 Below 1 Ω
      N 2 - 9, 4 - 5 Below 1 Ω
      D 2 - 7 Below 1 Ω
      2 2 - 3 Below 1 Ω
      L 2 - 8 Below 1 Ω
    4. Reconnect the park/neutral position switch connector.

    NG: REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLY (GO TO STEP   5  AFTER THE REPLACEMENT) 

    OK: Go to Next Step 

  3. INSPECT IGNITION SWITCH ASSEMBLY 
    1. Disconnect the 118 ignition switch connector.
    2. Measure the resistance between the connector terminals shown in the chart below.

      Standard resistance 

      STANDARD RESISTANCE

      Switch Position Tester Connection Specified Condition
      LOCK All Terminals 10 kΩ or higher
      ACC 2 - 3 Below 1 Ω
      ON 2 - 3, 2 - 4, 6 - 7 Below 1 Ω
      START 1 - 2, 2 - 4, 6 - 7, 7 - 8 Below 1 Ω
    3. Reconnect the ignition switch connector.
      Fig 2: Inspecting Ignition Switch Assembly
      G05843596Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPLACE IGNITION SWITCH ASSEMBLY (GO TO STEP   5  AFTER REPLACEMENT) 

    OK: Go to Next Step 

  4. READ VALUE OF TECHSTREAM (STARTER SIGNAL) 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch ON and turn the tester ON.
    3. On the Techstream, enter the following menus: Powertrain/Engine and ECT/Data List/All Data/Starter Signal.
    4. Read the values.

      OK 

      IGNITION SWITCH POSITION

      Ignition Switch Position Starter Signal
      ON OFF
      START ON

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to Next Step 

  5. CHECK WHETHER DTC OUTPUT RECURS (DTC P0617) 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch ON and turn the tester ON.
    3. Clear the DTCs.
    4. Drive the vehicle more than 25 mph (40 km/h) for 20 seconds or more.
    5. Read the DTCs.

      Result 

      RESULT REFERENCE

      Display (DTC Output) Proceed to
      P0617 A
      No DTC output B

    B: CHECK FOR INTERMITTENT PROBLEMS 

    A: REPLACE ECM 

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.