2008 Lexus GX 470FACTORY OEM SERVICE PROCEDURE

Typical Enabling Conditions

ALL:Β 

TYPICAL ENABLING CONDITIONS

Monitor will run whenever these DTCs are not present P0115 - P0118 (ECT sensor)
P0120 - P0223, P2135 (TP sensor)
P0125 (insufficient ECT for closed loop)
P0335 (CKP sensor)
Throttle position 0.24 V or more
Engine Running
Battery voltage 10.5 V or more
Engine coolant temperature 70Β°C (158Β°F) or more
IAT sensor circuit OK
ECT sensor circuit OK
CKP sensor circuit OK
TP sensor circuit OK
Canister pressure sensor circuit OK
Leak detection pump OK
Vent valve OK