2008 Lexus ES 350FACTORY OEM SERVICE PROCEDURE

Ignition Coil: Installation

  1. INSTALL IGNITION COIL ASSEMBLY 
    1. Install the 6 ignition coils with the 6 bolts.

      Torque: 10 N*m (102 kgf*cm, 7 ft.*lbf) 

    2. Connect the 6 ignition coil connectors.
  2. INSTALL NO. 1 SURGE TANK STAY 
    NOTE: DO NOT apply oil to the bolt listed below:
    TORQUE SPECIFICATION

    Tightening Parts
    No. 1 Surge tank stay and Cylinder head cover
    Fig 1: Locating Ignition Coils And Bolts
    G04975500Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Install the No. 1 surge tank stay with the bolt.

      Torque: 21 N*m (214 kgf*cm, 15 ft.*lbf) 

      Fig 2: Locating Bolt And No. 1 Surge Tank Stay
      G04975498Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Install the bolt and clamp.

      Torque: 10 N*m (102 kgf*cm, 7 ft.*lbf) 

      Fig 3: Locating Bolt And Harness Clamp
      G04975497Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSTALL INTAKE AIR SURGE TANK ASSEMBLY  (See INSTALLATION )
  4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY  (See INSTALLATION )
  5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL  (See INSTALLATION )
  6. ADD ENGINE COOLANT  (See ON-VEHICLE INSPECTION )
  7. CHECK FOR ENGINE COOLANT LEAKS  (See COOLING SYSTEM )
  8. INSTALL FRONT SUSPENSION UPPER CENTER BRACE  (See INSTALLATION )
  9. INSTALL V-BANK COVER SUB-ASSEMBLY  (See INSTALLATION )
  10. INSTALL ENGINE ROOM SIDE COVER LH  (See INSTALLATION )
  11. INSTALL ENGINE ROOM SIDE COVER RH  (See INSTALLATION )
  12. INSTALL COOL AIR INTAKE DUCT SEAL  (See INSTALLATION )
  13. PERFORM INITIALIZATION 
    1. Perform initialization procedure (See INITIALIZATION ).
      NOTE: Some vehicle systems require initialization after reconnecting the cable to the negative battery terminal.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.