HEATED OXYGEN SENSOR BANK 1 SENSOR 1 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $41 | $90 | Multiply by 0.001 [A] | Maximum sensor heater current | Minimum test | limit Maximum test limit |
HEATED OXYGEN SENSOR BANK 1 SENSOR 2 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $42 | $90 | Multiply by 0.001 [A] | Maximum sensor heater current | Minimum test limit | Maximum test limit |
HEATED OXYGEN SENSOR BANK 2 SENSOR 1 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $45 | $90 | Multiply by 0.001 [A] | Maximum sensor heater current | Minimum test limit | Maximum test limit |
HEATED OXYGEN SENSOR BANK 2 SENSOR 2 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $46 | $90 | Multiply by 0.001 [A] | Maximum sensor heater current | Minimum test limit | Maximum test limit |
THERMOSTAT
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $E1 | $E8 | Multiply by 01 [°C] | ECT sensor output when estimated ECT reaches to malfunction criteria | Malfunction criteria | Maximum test limit |
HEATED OXYGEN SENSOR BANK 1 SENSOR 1 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $01 | $03 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Lean that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Lean | Sensor voltage to define sensor status is Lean |
| $01 | $04 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Rich that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Rich | Sensor voltage to define sensor status is Rich |
| $01 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | Minimum test limit | Maximum test limit |
| $01 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | Minimum test limit | Maximum test limit |
| $01 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | 0 V | Malfunction criterion |
| $01 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Malfunction criterion | 1.0 V |
| $01 | $81 | Multiply by 0.001 [seconds] | Duration while sensor voltage stuck Lean or Rich | 0 | Malfunction criterion |
| $01 | $82 | Multiply by 0.001 [seconds] | Duration of one sensor frequency | Minimum test limit | Maximum test limit |
HEATED OXYGEN SENSOR BANK 2 SENSOR 1 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $05 | $03 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Lean that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Lean | Sensor voltage to define sensor status is Lean |
| $05 | $04 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Rich that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Rich | Sensor voltage to define sensor status is Rich |
| $05 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | Minimum test limit | Maximum test limit |
| $05 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | Minimum test limit | Maximum test limit |
| $05 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | 0 V | Malfunction criterion |
| $05 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Malfunction criterion | 1.0 V |
| $05 | $81 | Multiply by 0.001 [seconds] | Duration while sensor voltage stuck Lean or Rich | 0 | Malfunction criterion |
| $05 | $82 | Multiply by 0.001 [seconds] | Duration of one sensor frequency | Minimum test limit | Maximum test limit |
HEATED OXYGEN SENSOR BANK 1 SENSOR 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $02 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | 0 | Malfunction criterion |
| $02 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | 0 | Malfunction criterion |
| $02 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | Minimum test limit | Maximum test limit |
| $02 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Minimum test limit | Maximum test limit |
| $02 | $84 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was lower than 0.05 V | 0 | Malfunction criterion |
| $02 | $85 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was lower than 0.7 V | Malfunction criterion | 65,535 |
| $02 | $86 | Multiply by 0.1 [seconds] | Duration while sensor voltage was higher than 0.7 V | 0 | 65,535 |
| $02 | $87 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was higher than 0.45 V | Minimum test limit | 65,535 |
| $02 | $88 | Multiply by 0.1 [seconds] | Cumulative time that sub-feedback compensation factor remained 7% or more | 0 | Malfunction criterion |
| $02 | $89 | Multiply by 0.01526 [%] | Percentage in monitor time when sub-feedback compensation factor remained 0.05 V or more | 0 | Malfunction criterion |
| $02 | $8A | Multiply by 1 [time] | Frequency of sensor switching | 0 | Malfunction criterion |
| $02 | $8B | Multiply by 0.001 [seconds] | 0.35 V to 0.2 V sensor switch time | 0 | Maximum test limit |
| $02 | $8D | Multiply by 0.001 [seconds] | Duration that sensor voltage dropped to 0.2 V during fuel-cut | 0 | Malfunction criterion |
| $02 | $8F | Multiply by 0.001 [g] | Maximum oxygen storage capacity | 0 | Maximum test limit |
HEATED OXYGEN SENSOR BANK 2 SENSOR 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $06 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | 0 | Malfunction criterion |
| $06 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | 0 | Malfunction criterion |
| $06 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | Minimum test limit | Maximum test limit |
| $06 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Minimum test limit | Maximum test limit |
| $06 | $84 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was lower than 0.05 V | 0 | Malfunction criterion |
| $06 | $85 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was lower than 0.7 V | Malfunction criterion | 65,535 |
| $06 | $86 | Multiply by 0.1 [seconds] | Duration while sensor voltage was higher than 0.7 V | 0 | 65,535 |
| $06 | $87 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was higher than 0.45 V | Minimum test limit | 65,535 |
| $06 | $88 | Multiply by 0.1 [seconds] | Cumulative time that sub-feedback compensation factor remained 7% or more | 0 | Malfunction criterion |
| $06 | $89 | Multiply by 0.01526 [%] | Percentage in monitor time when sub-feedback compensation factor remained 0.05 V or more | 0 | Malfunction criterion |
| $06 | $8A | Multiply by 1 [time] | Frequency of sensor switching | 0 | Malfunction criterion |
| $06 | $8B | Multiply by 0.001 [seconds] | 0.35 V to 0.2 V sensor switch time | 0 | Maximum test limit |
| $06 | $8D | Multiply by 0.001 [seconds] | Duration that sensor voltage dropped to 0.2 V during fuel-cut | 0 | Malfunction criterion |
| $06 | $8F | Multiply by 0.001 [g] | Maximum oxygen storage capacity | 0 | Maximum test limit |
MISFIRE MONITOR - ALL CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A1 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - 1 CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A2 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A2 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - 2 CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A3 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A3 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - 3 CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A4 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A4 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - 4 CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A5 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A5 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - 5 CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A6 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A6 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - 6 CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A7 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A7 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - 7 CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A8 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A8 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - 8 CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A9 | $0B | Multiply by 1 [time] | Exponential weighted moving average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A9 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
CATALYST BANK 1 - USING HEATED OXYGEN SENSOR ON SENSOR 1 AND 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $21 | $A1 | Multiply by 0.0003 [no dimension] | Locus length ratio of heated oxygen sensor 1 and 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A2 | Multiply by 0.0003 [no dimension] | Voltage area ratio of heated oxygen sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A3 | Multiply by 0.0003 [no dimension] | Locus length ratio of heated oxygen sensor 1 and 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A4 | Multiply by 0.0003 [no dimension] | Heated oxygen sensor frequency ratio of sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A5 | Multiply by 0.0003 [no dimension] | Locus length ratio of heated oxygen sensor 1 and 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A6 | Multiply by 0.0003 [no dimension] | Voltage area ratio of heated oxygen sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
CATALYST BANK 2- USING HEATED OXYGEN SENSOR ON SENSOR 1 AND 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $22 | $A1 | Multiply by 0.0003 [no dimension] | Locus length ratio of heated oxygen sensor 1 and 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A2 | Multiply by 0.0003 [no dimension] | Voltage area ratio of heated oxygen sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A3 | Multiply by 0.0003 [no dimension] | Locus length ratio of heated oxygen sensor 1 and 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A4 | Multiply by 0.0003 [no dimension] | Heated oxygen sensor frequency ratio of sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A5 | Multiply by 0.0003 [no dimension] | Locus length ratio of heated oxygen sensor 1 and 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A6 | Multiply by 0.0003 [no dimension] | Voltage area ratio of heated oxygen sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
EVAP
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit | ||
|---|---|---|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.01 [kPa] | Test value for small leak (P0456) Refer to pressure D(1) | Minimum test limit for small leak | Maximum test limit for small leak | ||
| $3D | $CA | Multiply by 0.01 [kPa] | Test value for gross leak (P0455) Refer to pressure E(1) | Minimum test limit for gross leak | Maximum test limit for gross leak | ||
| $3D | $CB | Multiply by 0.01 [kPa] | Test value for vacuum pump stuck OFF (P2401) Refer to pressure A(1) | Minimum test limit for vacuum pump stuck OFF | Maximum test limit for vacuum pump stuck OFF | ||
| $3D | $CD | Multiply by 0.01 [kPa] | Test value for vacuum pump stuck ON (P2402) Refer to pressure A(1) | Minimum test limit for vacuum pump stuck ON | Maximum test limit for vacuum pump stuck ON | ||
| $3D | $CE | Multiply by 0.01 [kPa] | Test value for vent valve stuck OFF (vent) (P2420) Refer to pressure C(1) | Minimum test limit for vent valve stuck ON | Maximum test limit for vent valve stuck ON | ||
| $3D | $CF | Multiply by 0.01 [kPa] | Test value for vent valve stuck ON (P2419) Refer to pressure A(1) | Minimum test limit for vent valve stuck OFF | Maximum test limit for vent valve stuck OFF | ||
| $3D | $D0 | Multiply by 0.01 [kPa] | Test value for 0.02 inch orifice low flow (P043E) Refer to pressure B(1) | Minimum test limit for 0.02 inch orifice low flow | Maximum test limit for 0.02 inch orifice low flow | ||
| $3D | $D1 | Multiply by 0.01 [kPa] | Test value for 0.02 inch orifice high flow (P043F) Refer to pressure A(1) | Minimum test limit for 0.02 inch orifice high flow | Maximum test limit for 0.02 inch orifice high flow | ||
| $3D | $D4 | Multiply by 0.01 [kPa] | Test value for VSV (for EVAP) stuck close (P0441) Refer to pressure F(1) | Minimum test limit for VSV (for EVAP) stuck close | Maximum test limit for VSV (for EVAP) stuck close | ||
| $3D | $D5 | Multiply by 0.01 [kPa] | Test value for VSV (for EVAP) stuck open (P0441) Refer to pressure E(1) | Minimum test limit for VSV (for EVAP) stuck open | Maximum test limit for VSV (for EVAP) stuck open | ||
| $3D | $D7 | Multiply by 0.01 [kPa] | Test value for purge flow (P0441) Refer to pressure G(1) | Minimum test limit for purge flow | Maximum test limit for purge flow | ||
|
|||||||
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.
Rather have a pro handle this?
A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.
Comes to youSame-day available12-month warranty
Get a Free QuoteNo obligation. See pricing before you book.