Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Inspection Procedure
- CHECK THAT MIL IS ILLUMINATEDÂ
- Perform troubleshooting in accordance with the chart below.
ResultÂ
RESULT CHARTCondition Proceed to MIL remains on A MIL is not illuminated B
B: Go to step  5
A: Go to next stepÂ
- Perform troubleshooting in accordance with the chart below.
- CHECK IF MIL TURNS OFFÂ
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch ON and turn the tester ON.
- Check if DTCs have been stored (see DIAGNOSTIC TROUBLE CODE CHARTÂ ). If DTCs are present, write them down.
- Clear the DTCs (see DTC CHECK/CLEARÂ ).
- Check that the MIL turns off.
OK:Â
MIL turns off.Â
OK: REPAIR CIRCUITS INDICATED BY OUTPUT DTCSÂ
NG: Go to next stepÂ
- CHECK WIRE HARNESS (FOR SHORT)Â
- Disconnect the E5 ECM connector.
- Turn the ignition switch ON.
- Check that the MIL is not illuminated.
OK:Â
MIL is not illuminated.Â
OK: REPLACE ECMÂ
NG: Go to next stepÂ
- CHECK WIRE HARNESS (COMBINATION METER - ECM)Â
- Disconnect the C8 combination meter connector.
- Disconnect the E5 ECM connector.
- Measure the resistance of the wire harness side connectors.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition C8-6 (CHK) - E5-8 (W) Below 1 Ω C8-6 (CHK) or E5-8 (W) - Body ground 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS AND CONNECTORÂ
OK: REPAIR OR REPLACE COMBINATION METERÂ
- CHECK THAT MIL IS ILLUMINATEDÂ
- Check that the MIL is illuminated when turning the ignition switch ON.
OK:Â
MIL is illuminated.Â
OK: SYSTEM OKÂ
NG: Go to next stepÂ
- Check that the MIL is illuminated when turning the ignition switch ON.
- CHECK THAT ENGINE STARTSÂ
- Turn the ignition switch ON.
- Start the engine.
ResultÂ
RESULT CHARTResult Proceed to Engine starts A Engine dose not start* B HINT:
*: The intelligent tester cannot communicate with the ECM.
B: GO TOÂ VC OUTPUT CIRCUITÂ
A: Go to next stepÂ
- CHECK WIRE HARNESS (COMBINATION METER - BODY GROUND)Â
- Disconnect the E5 ECM connector.
- Turn the ignition switch ON.
- Measure the voltage of the wire harness side connectors
Standard voltageÂ
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition E5-8 (W) - Body ground 10 to 14 V
OK: REPLACE ECMÂ
NG: Go to next stepÂ
- CHECK WIRE HARNESS (COMBINATION METER - ECM)Â
- Disconnect the C8 combination meter connector.
- Disconnect the E5 ECM connector.
- Measure the resistance of the wire harness side connectors.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition C8-6 (CHK) - E5-8 (W) Below 1 Ω C8-6 (CHK) or E5-8 (W) - Body ground 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS AND CONNECTORÂ
OK: REPAIR OR REPLACE COMBINATION METERÂ
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.