Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Inspection Procedure
- INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
- Disconnect the park/neutral position switch connector.
- Gate shift lever type:
Measure resistance according to the value(s) in the table below when the shift lever is moved to each position.
Resistance
TESTER CONNECTION SPECIFIED CONDITIONShift Position Tester Connection Specified Condition P 2 - 6 and 4 - 5 Below 1 Ω Except P 10 kΩ or higher R 2 - 1 Below 1 Ω Except R 10 kΩ or higher N 2 - 9 and 4 - 5 Below 1 Ω Except N 10 kΩ or higher D and 4 2 - 7 Below 1 Ω Except D and 4 10 kΩ or higher 3 2 - 3 Below 1 Ω Except 3 10 kΩ or higher 2 and L 2 - 8 Below 1 Ω Except 2 and L 10 kΩ or higher - Shift lever with Multi-mode automatic transmission type: Measure resistance according to the value(s) in the table below when the shift lever is moved to each position.
Resistance
TESTER CONNECTION SPECIFIED CONDITIONShift Position Tester Connection Specified Condition P 2 - 6 and 4 - 5 Below 1 Ω Except P 10 kΩ or higher R 2 - 1 Below 1 Ω Except R 10 kΩ or higher N 2 - 9 and 4 - 5 Below 1 Ω Except N 10 kΩ or higher D, S, "+" and "-" 2 - 7 Below 1 Ω Except D, S, "+" and "-" 10 kΩ or higher
NG: REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLY
OK: Go to Next Step
- INSPECT TRANSMISSION SHIFT LEVER
- Connect the park/neutral position switch connector.
- Disconnect the transmission control switch connector of shift lock control unit assembly.
- Gate shift lever type:
Measure resistance according to the value(s) in the table below when the shift lever is moved to each position.
Resistance
TESTER CONNECTION SPECIFIED CONDITIONShift Position Tester Connection Specified Condition D 2 - 9 Below 1 Ω 4 10 kΩ or higher D 3 - 9 10 kΩ or higher 4 Below 1 Ω 2 5 - 10 Below 1 Ω L 10 kΩ or higher 2 4 - 10 10 kΩ or higher L Below 1 Ω - Shift lever with Multi-mode automatic transmission type: Measure resistance according to the value(s) in the table below when the shift lever is moved to each position.
Resistance
TESTER CONNECTION SPECIFIED CONDITIONShift Position Tester Connection Specified Condition S, "+" and "-" 3 - 8 Below 1 Ω Except S, "+" and "-" 10 kΩ or higher
NG: REPLACE TRANSMISSION CONTROL SWITCH OR SHIFT LOCK CONTROL UNIT ASSEMBLY
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (PARK/NEUTRAL POSITION SWITCH - ECM)
- Connect the transmission control switch connector of shift lock control unit assembly.
- Turn the ignition switch to the ON position, and measure the voltage according to the value(s) in the table below when the shift lever is moved to each position.
Voltage
TESTER CONNECTION SPECIFIED CONDITIONShift Position Tester Connection Specified Condition P and N E9 - 8 (NSW) - Body ground Below 2 V Except P and N 10 to 14 V P E6 - 23 (P) - Body ground 10 to 14 V Except P Below 1 V N E6 - 22 (N) - Body ground 10 to 14 V Except N Below 1 V R E6 -11 (R) - Body ground 10 to 14 V* Except R Below 1 V D and 4 E6 - 21 (D) - Body ground 10 to 14 V Except D and 4 Below 1 V 4 E6 - 20 (S) - Body ground 10 to 14 V Except 4 Below 1 V 3 E6 -19 (3) - Body ground 10 to 14 V Except 3 Below 1 V 2 and L E6 -10 (2) - Body ground 10 to 14 V Except 2 and L Below 1 V L E6 - 9 (L) - Body ground 10 to 14 V Except L Below 1 V HINT:
*: The voltage will drop slightly due to lighting up of the back up light. - Shift lever with Multi-mode automatic transmission type: Turn the ignition switch to the ON position, and measure the voltage according to the value(s) in the table below when the shift lever is moved to each position.
Voltage
TESTER CONNECTION SPECIFIED CONDITIONShift Position Tester Connection Specified Condition P and N E9 - 8 (NSW) - Body ground Below 2 V Except P and N 10 to 14 V P E6 - 23 (P) - Body ground 10 to 14 V Except P Below 1 V N E6 - 22 (N) - Body ground 10 to 14 V Except N Below 1 V R E6 -11 (R) - Body ground 10 to 14 V* Except R Below 1 V D and S E6 - 21 (D) - Body ground 10 to 14 V Except D and S Below 1 V S, "+" and "-" E6 - 20 (S) - Body ground 10 to 14 V Except S, "+" and "-" Below 1 V HINT:
*: The voltage will drop slightly due to lighting up of the back up light.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE ECM
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.