2007 Lexus RX 350 AWDFACTORY OEM SERVICE PROCEDURE

Intake System: Inspection

  1. INSPECT INTAKE AIR CONTROL VALVE 
    Fig 1: Applying Battery Voltage Between Terminals
    G04975205Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Inspection procedure when applying voltage between terminals
      1. Disconnect the connector from the intake air control valve.
      2. Apply battery voltage between terminals 1 (-) and 2 (+) of the intake air control valve.

        Check that a clicking sound is heard from the intake air control valve.

        If the result is not as specified, replace the intake air surge tank.

  2. INSPECT AIR CLEANER ASSEMBLY 
    Fig 2: Applying Vacuum To Actuator
    G04975206Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Apply 26.6 kPa (200 mmHg, 7.9 in.Hg) of vacuum to the actuator. Check if the valve rotates open.
    2. Apply vacuum for 1 minute. The actuator should continue to keep the valve open.

      If the result is not as specified, replace the air cleaner assembly.