Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2007 Lexus LS 460LFACTORY OEM SERVICE PROCEDURE
Diagnostic Procedure
WARNING: This page is about a different car, the 2004 Nissan Quest. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK REFRIGERANT PRESSURE SENSOR OVERALL FUNCTIONÂ
- Start engine and warm it up to normal operating temperature.
- Turn A/C switch and blower switch ON.
- Check voltage between ECM terminal 70 and ground with CONSULT-II or tester.
- Voltage: 1.0 - 4.0VÂ
OK or NGÂ
- OK: INSPECTION ENDÂ
- NG: GO TO 2.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUITÂ
- Turn A/C switch and blower switch OFF.
- Stop engine.
- Disconnect refrigerant pressure sensor harness connector.
- Turn ignition switch ON.
- Check voltage between refrigerant pressure sensor terminal 1 and ground with CONSULT-II or tester.
Courtesy of NISSAN MOTOR CO., U.S.A.
- Voltage: Approximately 5VÂ
Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NGÂ
- OK: GO TO Â 4 .
- NG: GO TO 3.
- DETECT MALFUNCTIONING PARTÂ
Check the following.
- Harness connectors E19, F33
- Harness for open or short between ECM and refrigerant pressure sensor
- Repair harness or connectors.
- CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORTÂ
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Disconnect TCM harness connector.
- Check harness continuity between refrigerant pressure sensor terminal 3 and ECM terminal 67, TCM terminal 42.
Refer to WIRING DIAGRAMÂ .
- Continuity should exist.Â
- Also check harness for short to ground or short to power.
OK or NGÂ
- OK: GO TO Â 6 .
- NG: GO TO 5.
- DETECT MALFUNCTIONING PARTÂ
Check the following.
- Harness connectors E19, F33
- Harness for open or short between ECM and refrigerant pressure sensor
- Harness for open or short between TCM and refrigerant pressure sensor
- Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORTÂ
- Check harness continuity between ECM terminal 70 and refrigerant pressure sensor terminal 2.
Refer to WIRING DIAGRAMÂ .
- Continuity should exist.Â
- Also check harness for short to ground and short to power.
OK or NGÂ
- OK: GO TO Â 8 .
- NG: GO TO 7.
- Check harness continuity between ECM terminal 70 and refrigerant pressure sensor terminal 2.
- DETECT MALFUNCTIONING PARTÂ
Check the following.
- Harness connectors E19, F33
- Harness for open or short between ECM and refrigerant pressure sensor
- Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENTÂ
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENTÂ .
OK or NGÂ
- OK: Replace refrigerant pressure sensor.
- NG: Repair or replace.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.