2007 Lexus LS 460FACTORY OEM SERVICE PROCEDURE

Floor Shift Assembly: Inspection

  1. INSPECT TRANSMISSION CONTROL SWITCH 
    Fig 1: Identifying Transmission Control Switch Connector Terminals
    G04948536Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Shift Lever Position Specified Condition
      3(IG)-7(S) S, "+" and "-" Below 1 Ω
      2 (SFTU) - 5 (E) Continuously shift to "+" (Up-shift) Below 1 Ω
      1 (SFTD) - 5 (E) Continuously shift to "-" (Down-shift) Below 1 Ω
      3 (IG) - 7 (S) Not on S, "+" and "-" 10 kΩ or higher
      2 (SFTU) - 5 (E) S 10 kΩ or higher
      1 (SFTD) - 5 (E) S 10 kΩ or higher

      If the resistance value is not as specified, replace the transmission floor shift assembly.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.