2007 Lexus GX 470FACTORY OEM SERVICE PROCEDURE

On-Vehicle Inspection

  1. INSPECT DEFOGGER RELAY (Marking: DEFOG) 
    Fig 1: Identifying Defogger Relay Connector Terminals
    G05266818Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

    RESISTANCE SPECIFICATION TABLE

    Tester Condition Specified Condition
    3 - 4 Below 1 Ω (when battery voltage is not applied between terminals)
    3 - 5 10 kΩ or higher (when battery voltage is not applied between terminals)
    3 - 5 Below 1 Ω (when battery voltage is applied to terminals 1 and 2)

    If the result is not as specified, replace the relay.

Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.