Inspection Procedure
- CHECK FUEL PUMP OPERATIONÂ
- Check if there is pressure in the fuel inlet hose.
HINT:
If there is fuel pressure, you will hear the sound of fuel flowing.
OK: Go to step  12
NG: Go to next stepÂ
- Check if there is pressure in the fuel inlet hose.
- PERFORM ACTIVE TEST (OPERATE C/OPN RELAY)Â
- Connect the intelligent tester to the CAN VIM. Then connect the CAN VIM to the DLC3.
- Turn the engine switch on (IG) and turn the tester ON.
- Enter the following menus: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / FUEL PUMP / SPD.
- Check the relay operation while operating it using the tester.
OK:Â
Operating noise can be heard from the relay.Â
OK: Go to step  8
NG: Go to next stepÂ
- INSPECT ECM POWER SOURCE CIRCUITÂ
NG: REPAIR ECM POWER SOURCE CIRCUITÂ
OK: Go to next stepÂ
- INSPECT FUSE (F/PUMP)Â
- Remove the F/PMP fuse from the engine room No. 2 junction block.
- Measure the resistance of the fuse.
Standard resistance:Â
Below 1 ΩÂ
NG: CHECK FOR SHORT IN ALL HARNESSES AND COMPONENTS CONNECTED TO FUSE, AND REPLACE FUSEÂ
OK: Go to next stepÂ
- INSPECT INTEGRATION RELAY (Marking EFI NO. 2)Â
- Remove the integration relay from the engine room No. 2 junction block.
- Measure the resistance of the EFI NO. 2 relay.
Standard resistanceÂ
TERMINAL CONNECTIONS SPECIFIED CONDITION CHARTTerminal Connections Specified Condition 2B-7 - 2C-1 10 kΩ or higher 2B-7 - 2C-1 Below 1 Ω
(when battery voltage is applied to terminals 2A-8 and 2B-3)
NG: REPLACE INTEGRATION RELAYÂ
OK: Go to next stepÂ
- CHECK WIRE HARNESS (ECM - C/OPN RELAY)Â
- Remove the integration relay from the engine room No. 2 junction block.
- Disconnect the A6 ECM connector.
- Measure the resistance of the wire harness side connectors.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition 2B-7 - A6-14 (FC) Below 1 Ω 2B-7 or A6-14 (FC) - Body ground 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS AND CONNECTORÂ
OK: Go to next stepÂ
- CHECK ECM (FC VOLTAGE)Â
- Turn the engine switch on (IG).
- Measure the voltage of the ECM connector.
Standard voltageÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition A6-14 (FC) - E7-7 (E1) 9 to 14 V
OK: REPLACE ECMÂ
NG: REPLACE INTEGRATION RELAYÂ
- INSPECT RELAY (Marking: F/PMP)Â
- Remove the F/PMP relay from the engine room No. 2 relay block.
- Measure the resistance of the relay.
Standard resistanceÂ
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition 3 - 4 Below 1 Ω 3 - 4 10 kΩ or more
(when battery voltage is applied to terminals 1 and 2)
NG: REPLACE RELAYÂ
OK: Go to next stepÂ
- INSPECT FUEL PUMPÂ
- Check the resistance of the fuel pump.
- Measure the resistance between terminals 4 and 5.
Standard resistance:Â
0.2 to 3.0 Ω at 20°C (68°F)Â
- Measure the resistance between terminals 4 and 5.
- Check operation of the fuel pump.
- Apply battery voltage to both terminals. Check that the pump operates.NOTE:
- These tests must be done quickly (within 10 seconds) to prevent the coil from burning out.
- Keep fuel pump as far away from the battery as possible.
- Apply battery voltage to both terminals. Check that the pump operates.
- Check the resistance of the fuel pump.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.