2006 Lexus SC 430FACTORY OEM SERVICE PROCEDURE

LS 430

FRONT HEATED OXYGEN SENSOR BANK 1 SENSOR 1

Monitor ID Test ID Scaling Unit Description of Test Value
$01 $03 Multiply by 0.001 V Criteria of Lean sensor
O2S is Lean when voltage is lower than this value
$01 $04 Multiply by 0.001 V Criteria of Rich sensor
O2S is Rich when voltage is higher than this value
$01 $05 Multiply by 0.001 Seconds Rich - Lean switch time
$01 $06 Multiply by 0.001 Seconds Lean - Rich switch time
$01 $07 Multiply by 0.005 V Minimum sensor voltage
$01 $08 Multiply by 0.005 V Maximum sensor voltage
$01 $81 Multiply by 0.001 Seconds Duration while sensor voltage stuck Lean or Rich
$01 $82 Multiply by 0.001 Seconds Time of one cycle of sensor output
FRONT HEATED OXYGEN SENSOR BANK 2 SENSOR 1

MID TID Scaling Unit Description
$05 $03 Multiply by 0.001 V Criteria of Lean sensor
O2S is Lean when voltage is lower than this value
$05 $04 Multiply by 0.001 V Criteria of Rich sensor
O2S is Rich when voltage is higher than this value
$05 $05 Multiply by 0.001 Seconds Rich - Lean switch time
$05 $06 Multiply by 0.001 Seconds Lean - Rich switch time
$05 $07 Multiply by 0.005 V Minimum sensor voltage
$05 $08 Multiply by 0.005 V Maximum sensor voltage
$05 $81 Multiply by 0.001 Seconds Duration while sensor voltage stuck Lean or Rich
$05 $82 Multiply by 0.001 Seconds Time of one cycle of sensor output
REAR HEATED OXYGEN SENSOR BANK 1 SENSOR 2

MID TID Scaling Unit Descriptio
$02 $05 Multiply by 0.001 Seconds Rich - Lean switch time
$02 $06 Multiply by 0.001 Seconds Lean - Rich switch time
$02 $07 Multiply by 0.001 V Minimum sensor voltage
$02 $08 Multiply by 0.001 V Maximum sensor voltage
$02 $84 Multiply by 0.01526 % Percentage of time that sensor voltage is lower than 0.05 V
$02 $85 Multiply by 0.01526 % Percentage of time that sensor voltage is higher than 0.7 V
$02 $86 Multiply by 0.1 Seconds Duration that sensor voltage is higher than 0.45 V
$02 $87 Multiply by 0.01526 % Percentage of time that sensor voltage is higher than 0.45 V
$02 $88 Multiply by 0.1 Seconds Cumulative time that sub-feedback compensation factor remained 7% or more
$02 $89 Multiply by 0.01526 % Percentage of time that sub-feedback compensation factor remained 0.05 V or more
$02 $8A Multiply by 1 Time Frequency of sensor switching
$02 $8B Multiply by 0.001 Seconds 0.35 - 0.2 V sensor switch time
$02 $8D Multiply by 0.001 Seconds Duration that sensor voltage drops to 0.2 V during fuel-cut
$02 $8F Multiply by 0.001 Grams Maximum oxygen storage capacity
REAR HEATED OXYGEN SENSOR BANK 2 SENSOR 2

MID TID Scaling Unit Description
$06 $05 Multiply by 0.001 Seconds Rich - Lean switch time
$06 $06 Multiply by 0.001 Seconds Lean - Rich switch time
$06 $07 Multiply by 0.001 V Minimum sensor voltage
$06 $08 Multiply by 0.001 V Maximum sensor voltage
$06 $84 Multiply by 0.01526 % Percentage of time that sensor voltage is lower than 0.05 V
$06 $85 Multiply by 0.01526 % Percentage of time that sensor voltage is higher than 0.7 V
$06 $86 Multiply by 0.1 Seconds Duration that sensor voltage is higher than 0.45 V
$06 $87 Multiply by 0.01526 % Percentage of time that sensor voltage is higher than 0.45 V
$06 $88 Multiply by 0.1 Seconds Cumulative time that sub-feedback compensation factor remained 7% or more
$06 $89 Multiply by 0.01526 % Percentage of time that sub-feedback compensation factor remained 0.05 V or more
$06 $8A Multiply by 1 Time Frequency of sensor switching
$06 $8B Multiply by 0.001 Seconds 0.35 - 0.2 V sensor switch time
$06 $8D Multiply by 0.001 Seconds Duration that sensor voltage drops to 0.2 V during fuel-cut
$06 $8F Multiply by 0.001 Grams Maximum oxygen storage capacity
BANK 1 CATALYST - FRONT O2S AND REAR O2S TYPE

MID TID Scaling Unit Description
$21 $A1 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$21 $A2 Multiply by 0.0003 No dimension Voltage area ratio of O2S sensor 1 and sensor 2
$21 $A3 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$21 $A4 Multiply by 0.0003 No dimension O2S frequency ratio of sensor 2 and sensor 1
$21 $A5 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$21 $A6 Multiply by 0.0003 No dimension Voltage area ratio of O2S sensor 1 and sensor 2
BANK 2 CATALYST - FRONT O2S AND REAR O2S TYPE

MID TID Scaling Unit Description
$22 $A1 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$22 $A2 Multiply by 0.0003 No dimension Voltage area ratio of O2S sensor 1 and sensor 2
$22 $A3 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$22 $A4 Multiply by 0.0003 No dimension O2S frequency ratio of sensor 2 and sensor 1
$22 $A5 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$22 $A6 Multiply by 0.0003 No dimension Voltage area ratio of O2S sensor 1 and sensor 2
EVAP - KEY-OFF TYPE

MID TID Scaling Unit Description
$3D $C9 Multiply by 0.01 kPa Test value for small leak (P0456)
$3D $CA Multiply by 0.01 kPa Test value for gross leak (P0455)
$3D $CB Multiply by 0.01 kPa Test value for leak detection pump OFF stuck (P2401)
$3D $CD Multiply by 0.01 kPa Test value for leak detection pump ON stuck (P2402)
$3D $CE Multiply by 0.01 kPa Test value for vent valve OFF stuck (P2420)
$3D $CF Multiply by 0.01 kPa Test value for vent valve ON stuck (P2419)
$3D $D0 Multiply by 0.01 kPa Test value for reference orifice low flow (P043E)
$3D $D1 Multiply by 0.01 kPa Test value for reference orifice high flow (P043F)
$3D $D4 Multiply by 0.01 kPa Test value for purge VSV close stuck (P0441)
$3D $D5 Multiply by 0.01 kPa Test value for purge VSV open stuck (P0441)
$3D $D7 Multiply by 0.01 kPa Test value for purge flow insufficient (P0441)
OXYGEN SENSOR HEATER BANK 1 SENSOR 1

MID TID Scaling Unit Description
$41 $90 Multiply by 0.001 A Maximum sensor heater current
OXYGEN SENSOR HEATER BANK 1 SENSOR 2

MID TID Scaling Unit Description
$42 $90 Multiply by 0.001 A Maximum sensor heater current
OXYGEN SENSOR HEATER BANK 2 SENSOR 1

MID TID Scaling Unit Description
$45 $90 Multiply by 0.001 A Maximum sensor heater current
OXYGEN SENSOR HEATER BANK 2 SENSOR 2

MID TID Scaling Unit Description
$46 $90 Multiply by 0.001 A Maximum sensor heater current
MISFIRE - ALL CYLINDERS

MID TID Scaling Unit Description
$A1 $0B Multiply by 1 Time Exponential Weighted Moving Average (EWMA) misfire counts for last ten driving cycles - Total
$A1 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MISFIRE - CYLINDER 1

MID TID Scaling Unit Description
$A2 $0B Multiply by 1 Time EWMA misfire counts for last ten driving cycles - Total
$A2 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MISFIRE - CYLINDER 2

MID TID Scaling Unit Description
$A3 $0B Multiply by 1 Time EWMA misfire counts for last ten driving cycles - Total
$A3 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MISFIRE - CYLINDER 3

MID TID Scaling Unit Description
$A4 $0B Multiply by 1 Time EWMA misfire counts for last ten driving cycles - Total
$A4 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MISFIRE - CYLINDER 4

MID TID Scaling Unit Description
$A5 $0B Multiply by 1 Time EWMA misfire counts for last ten driving cycles - Total
$A5 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MISFIRE - CYLINDER 5

MID TID Scaling Unit Description
$A6 $0B Multiply by 1 Time EWMA misfire counts for last ten driving cycles - Total
$A6 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MISFIRE - CYLINDER 6

MID TID Scaling Unit Description
$A7 $0B Multiply by 1 Time EWMA misfire counts for last ten driving cycles - Total
$A7 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MISFIRE - CYLINDER 7

MID TID Scaling Unit Description
$A8 $0B Multiply by 1 Time EWMA misfire counts for last ten driving cycles - Total
$A8 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MISFIRE - CYLINDER 8

MID TID Scaling Unit Description
$A9 $0B Multiply by 1 Time EWMA misfire counts for last ten driving cycles - Total
$A9 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
THERMOSTAT

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$E1 $E8 Multiply by 0.1 [°C] ECT sensor output when estimated ECT reached to malfunction criteria Malfunction criteria Maximum test limit
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.