2006 Lexus IS 350FACTORY OEM SERVICE PROCEDURE

Fuel Pump Control Circuit: Wiring Diagram

Refer to DTC P0230  .

  1. CHECK FUEL PUMP OPERATION 
    1. Check if there is pressure in the fuel inlet hose.

      HINT:

      If there is fuel pressure, you will hear the sound of fuel flowing.

    OK : Go to step   12 

    NG : GO TO NEXT STEP 

  2. PERFORM ACTIVE TEST BY INTELLIGENT TESTER (OPERATE CIRCUIT OPENING RELAY) 
    1. Connect the intelligent tester to the DLC3.
    2. Turn the engine switch on (IG) and turn the intelligent tester on.
    3. Enter the following menus: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / FUEL PUMP / SPD.
    4. Check the operation of the relay while operating it using the intelligent tester.

      OK: Operating noise can be heard from the relay. 

    OK : Go to step   8 

    NG : GO TO NEXT STEP 

  3. INSPECT ECM POWER SOURCE CIRCUIT 
    1. Check the ECM POWER SOURCE CIRCUIT  .

      Standard voltage: 9 to 14 V 

    NG : REPAIR OR REPLACE POWER SOURCE CIRCUIT 

    OK : GO TO NEXT STEP 

  4. INSPECT FUSE (F/PMP FUSE) 
    1. Remove the F/PMP fuse from the engine room J/B and R/B No. 2.
    2. Measure the resistance of the F/PMP fuse.
      Fig 1: Identifying F/PMP Fuse
      G04054879Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard resistance: Below 1 Ω 

    NG : REPLACE F/PMP FUSE 

    OK : GO TO NEXT STEP 

  5. INSPECT INTEGRATION RELAY (EFI NO. 2 RELAY) 
    1. Remove the integration relay from the engine room J/B and R/B No. 2.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition
      2B-4 - 2C-1 10 kΩ or higher
      2B-4 - 2C-1 Below 1 Ω (when battery voltage applied to terminals 2B-3 and 2B-2)
      Fig 2: Identifying Integration Relay
      G04054880Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG : REPLACE INTEGRATION RELAY 

    OK : GO TO NEXT STEP 

  6. INSPECT INTEGRATION RELAY (C/OPN RELAY) 
    1. Remove the integration relay from the engine room J/B and R/B No. 2.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition
      2B-6 - 2B-8 10 kΩ or higher
      2B-6 - 2B-8 Below 1 Ω (when battery voltage applied to terminals 2B-6 and 2B-7)
      Fig 3: Identifying Integration Relay
      G04054881Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG : REPLACE INTEGRATION RELAY 

    OK : GO TO NEXT STEP 

  7. INSPECT ECM (FC VOLTAGE) 
    1. Turn the engine switch on (IG).
    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage 

      VOLTAGE SPECIFICATION

      Tester Connection Specified Condition
      FC (A5-14) - E1 (E4-7) 9 to 14 V
      Fig 4: Identifying ECM Connectors
      G04054882Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    OK : REPLACE ECM 

    NG : CHECK AND REPAIR HARNESS AND CONNECTOR (ECM - CIRCUIT OPENING RELAY) 

  8. INSPECT F/PMP RELAY 
    1. Remove the F/PMP relay from the engine room J/B and R/B No. 2.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition
      3 - 4 10 kΩ or higher
      3 - 4 Below 1 Ω (when battery voltage applied to terminals 1 and 2)
      Fig 5: Identifying Relay Test Terminals
      G04054635Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG : REPLACE F/PMP RELAY 

    OK : GO TO NEXT STEP 

  9. INSPECT FUEL PUMP 
    1. Inspect fuel pump resistance.
      1. Measure the resistance between terminals 4 and 5.

        Standard resistance: 0.2 to 3.0 Ω at 20°C (68°F) 

    2. Inspect fuel pump operation.
      1. Apply battery voltage to both terminals. Check that the pump operates.
        Fig 6: Identifying Fuel Pump Connectors
        G04054884Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.