Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
2005 Lexus ES 330FACTORY OEM SERVICE PROCEDURE
Inspection Procedure
WARNING: This page is about a different car, the 2005 Toyota Sienna. However, it is still accessible from the selected car via links, so may be relevant.
- INSPECT FUSE (PWR, ECU-IG, AM1)
- Remove the fuses from the instrument panel J/B.
- Check the resistance.
Standard: Below 1 Ω
- NG: REPLACE FUSE
- OK: GO TO NEXT STEP
- INSPECT RELAY (IG1, PWR)
- Remove the relay from the instrument panel J/B.
- Check the resistance of the relay.
Standard:
TERMINAL SPECIFIED CONDITIONTerminal No. Specified Condition 3 - 5 10 KΩ or higher Below 1 Ω
(When battery voltage is applied to terminals 1 and 2)
- NG: REPLACE RELAY
- OK: GO TO NEXT STEP
- CHECK WIRE HARNESS (TO INSTRUMENT JUNCTION BLOCK ASSY)
- Disconnect the 1A, 1H and 1L J/B connectors.
- Check the voltage and resistance between each terminal of the wire harness side connector and the body ground.
Standard:
TERMINAL SPECIFIED CONDITIONTerminal No. Condition Specified Condition 1A-1 - Body ground Constant 10 to 14 V 1L-16 - Body ground Constant Below 1 Ω 1H-10 - 1H-29 Ignition switch ON Below 1 Ω
- NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
- OK: GO TO NEXT STEP
- CHECK WIRE HARNESS (TO POWER WINDOW REGULATOR MASTER SWITCH)
- Disconnect the D9 master switch connector.
- Check the voltage or resistance between each terminal of the wire harness side connector and the body ground.
Standard:
TERMINAL SPECIFIED CONDITIONTerminal No. Condition Specified Condition D9-6 (B) - Body ground Ignition switch ON 10 to 14 V D9-11 (IG) - Body ground 10 D9-1 (E) - Body ground Constant Below 1 Ω
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- OK: REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSY
- NG: GO TO NEXT STEP
- CHECK WIRE HARNESS (INSTRUMENT JUNCTION BLOCK ASSY - POWER WINDOW MASTER SWITCH)
- Disconnect the 1L and 1K J/B connectors.
- Disconnect the D9 master switch connector.
- Check the resistance between the wire harness side connectors.
Standard:
TERMINAL SPECIFIED CONDITIONTerminal No. Specified Condition 1K-20 - D9-6 (B) Below 1 Ω 1L-23 - D9-11 (IG)
- NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
- OK: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSY
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.