2002 Lexus ES 300FACTORY OEM SERVICE PROCEDURE

Generator Specifications

GENERATOR SPECIFICATIONS

Application Specification
Brush Length
Standard 0.413 in. (10.5 mm)
Limit (Minimum) .059 in. (1.5 mm)
Rotor
Resistance 2.1-2.5 Ohms
Measured @ 68°F (20°C)
Slip Ring Diameter
Standard 0.559-0.567 in. (14.2-14.4 mm)
Minimum 0.504 in. (12.8 mm)
Generator Regulated Output
Voltage Regulator
Voltage Regulating 13.2-14.8 Volts
Battery
Voltage 12.5-12.9 Volts
Measured @ 68°F (20°C)