2000 Lexus SC 300FACTORY OEM SERVICE PROCEDURE

Shift Speed Specifications

SHIFT SPEED SPECIFICATIONS

Application MPH
"D" Range
NORM Or PWR
1st-2nd (1) 35-40
2nd-3rd (1) 67-73
3rd-OD (1) 104-111
3rd-OD (2) 22-25
OD-3rd (2) 11-14
OD-3rd (1) 100-105
3rd-2nd (1) 62-66
2nd-1st (1) 27-30
"2" Range
NORM Or PWR
1st-2nd (1) 35-40
3rd-2nd (3) 80-84
2nd-1st (1) 27-30
"L" Range
NORM Or PWR
2nd-1st (3) 35-38
(1) Wide open throttle.
(2) Fully closed throttle.
(3) Wide open or fully closed throttle.
LOCK-UP SPEED SPECIFICATIONS (1)

Application MPH
"D" Range (2)
Lock-Up On In 3rd (3) 35-38
Lock-Up Off In 3rd (3) 34-37
Lock-Up On In OD 34-37
Lock-Up Off In OD 33-36
(1) Throttle valve opened 5 percent.
(2) No lock-up in "L" or "2" range.
(3) With OD switch off.
Factory Service Tools