2000 Lexus LX 470FACTORY OEM SERVICE PROCEDURE

Park/Neutral Switch Continuity Check

Disconnect electrical connector from park/neutral switch at transmission or transaxle. Using ohmmeter, check for continuity at specified terminals with gearshift lever in proper positions. See Fig 1. See PARK/NEUTRAL SWITCH SPECIFICATIONSΒ  table. If continuity is not as specified, replace switch.

PARK/NEUTRAL SWITCH SPECIFICATIONS

Application & Gearshift Lever Position Continuity Between Terminals No.
Avalon & Sienna
Park 5 & 6, 2 & 7
Reverse 2 & 8
Neutral 5 & 6, 2 & 9
Drive 2 & 10
2 2 & 3
Low 2 & 4
Camry, Camry Solara, & 4Runner
Park 5 & 6, 4 & 7
Reverse 4 & 8
Neutral 5 & 6, 4 & 10
Drive 4 & 9
2 4 & 2
Low 3 & 2
Celica & Land Cruiser
Park 6 & 9, 3 & 1
Reverse 3 & 2
Neutral 6 & 9, 3 & 5
Drive 3 & 7
2 3 & 4
Low 3 & 8
ECHO
Park 3 &5, 6 & 9
Reverse 3 & 4
Neutral 1 & 3, 6 & 9
Drive 3 & 8
2 2 & 3
Low 3 & 7
Tacoma
Park 5 & 6, 4 & 7
Reverse 4 & 8
Neutral 5 & 6, 4 & 10
Drive 4 & 9
2 4 & 2
Low 4 & 3
Tundra
Park 4 & 7, 5 & 6
Reverse 4 & 8
Neutral 4 & 10, 5 & 6
Drive 4 & 9
2 4 & 2
Low 4 & 3
Fig 1: Identifying Park/Neutral Switch Terminals
G94E45918Courtesy of Β© TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.