2000 Lexus LX 470FACTORY OEM SERVICE PROCEDURE

Charging System - Generators & Regulators: Overhaul: Generator: Disassembly

  1. Remove rear end cover (if equipped). See Figure. Remove brush holder and IC regulator. Remove diode assembly. Remove rubber insulators or seal plate (if equipped). Use generator Pulley Set Nut Wrench Set (SST 09820-63010) to remove generator pulley.
  2. To remove pulley, install SST "A" and "B" to rotor shaft and tighten SST "B" clockwise to 29 ft. lbs. (39 N.m). See Figure. Place SST "C" securely into a vise. Verify that SST "A" is secured to rotor shaft and install SST "A" and "B" and generator into SST "C". Turn SST "A" in correct direction to loosen pulley nut. See Figure. To prevent damage to rotor shaft, DO NOT loosen pulley nut more than 1/2 turn. Remove SST "A" and "B" and generator from SST "C". Remove SST "A" and "B" from rotor shaft, and remove pulley nut and pulley.
  3. Remove rectifier and frame using appropriate puller. Remove generator washer (if equipped). Remove rotor from drive end frame (stator).
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.