2000 Lexus ES 300 V6-3.0L (1MZ-FE)FACTORY OEM SERVICE PROCEDURE

Control Module HVAC: Service and Repair


Blower Motor Linear Controller


1. REMOVE LOWER NO.1 PANEL

Factory service manual diagram



2. REMOVE HEATER PROTECTOR
Release the 3 claws and pull out the heater protector.

Factory service manual diagram



3. REMOVE BLOWER MOTOR LINEAR CONTROLLER
a. Disconnect the connector.
b. Remove the 2 screws and controller.

4. INSPECT BLOWER MOTOR LINEAR CONTROLLER

5. INSTALL BLOWER MOTOR LINEAR CONTROLLER
a. Install the controller with the 2 screws.
b. Connect the connector.

6. INSTALL HEATER PROTECTOR
7. INSTALL LOWER NO.2 PANEL
REMOVAL
1. REMOVE THESE PARTS:
a. No.1 instrument lower panel.
b. Instrument lower panel LH.

Factory service manual diagram



2. REMOVE BLOWER MOTOR LINEAR CONTROLLER
a. Disconnect the connector.
b. Remove the 2 screws and controller.

INSTALLATION
Installation is in the reverse order of removal.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.