1999 Lexus SC 400FACTORY OEM SERVICE PROCEDURE

Fuel Pump

FUEL PUMP PERFORMANCE

Application (1) Pressure psi (kg/cm2 )
ES300, GS300, GS400, LS400, RX300, SC300 & SC400 44-50 (3.1-3.5)
LX470 38-44 (2.7-3.1)
(1) Check fuel pressure with engine off and using scan tool connected to data link connector No. 3 with ignition on to activate fuel pump or by connecting battery voltage to terminals on electric fuel pump.
REGULATED FUEL PRESSURE

Application At Idle W/Vacuum psi (kg/cm2 ) At Idle W/O Vacuum psi (kg/cm2 )
ES300, GS300, GS400, LS400, RX300, SC300 & SC400 (1) (1)
LX470 28-34 (2.0-2.4) 38-44 (2.7-3.1)
(1) Fuel pressure should be 44-50 psi (3.1-3.5 kg/cm2 ) with engine idling. Fuel pressure regulator is not vacuum controlled, as fuel pressure regulator is mounted on electric fuel pump in the fuel tank.
FUEL PUMP RESISTANCE

Application Ohms @ 68Β°F (20Β°C)
All Models .2-3.0
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.