1996 Lexus ES 300FACTORY OEM SERVICE PROCEDURE

IAC Valve Resistance

Disconnect IAC valve connector. Measure resistance between terminals +B and RSC, and between terminals +B and RSO at IAC valve. See Fig 1. If resistance is not 17-25 ohms (cold) or 22-29 ohms (hot), replace IAC valve. If resistance is as specified, reconnect IAC valve connector. Go to next procedure.

Fig 1: Operating Idle Air Control (IAC) Valve
G94J45285Courtesy of Β© TOYOTA, LICENSE AGREEMENT TMS1002