1994 Lexus ES 300FACTORY OEM SERVICE PROCEDURE

DLC No. 3 Inspection

  1. If scan tester displays UNABLE TO CONNECT TO VEHICLE when scan tester is connected, try scan tester on another vehicle. If scan tester operates on another vehicle, proceed to step 2). If scan tester does not operate on another vehicle, problem is probably with scan tester.
  2. Note location of DLC No. 3 and DLC No. 3 terminals. See Figure and Fig 1 . Ensure voltage and resistance is correct at specified terminals when checking between terminal on Data Link Connector (DLC) No. 3 and body ground. See DLC NO. 3 VOLTAGE & RESISTANCE SPECIFICATIONS table. If voltage and resistance is not as specified, check wiring Circuit See appropriate wiring diagram at the end of this article.
NOTE: Terminal No. 2 on DLC No. 3 provides the pulse generation during the information transmission from the Engine Control Module (ECM).
DLC NO. 3 VOLTAGE & RESISTANCE SPECIFICATIONS

Terminal No. (Application) Specification
4 (Chassis Ground) Always One Ohm Or Less
5 (Signal Ground) Always One Ohm Or Less
16 (Battery Positive) Always 9-14 Volts
Fig 1: DLC No. 3 Terminal ID
G94C45353Courtesy of Β© TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.