1993 Lexus SC 400FACTORY OEM SERVICE PROCEDURE

Power Mirror Position Sensor Test

  1. Disconnect power mirror motor harness connector. Connect three 1.5-volt dry cell batteries together in series. Connect positive lead from dry cell assembly to mirror motor connector terminal No. 5 and negative lead to terminal No. 9. See Fig 1.
    Fig 1: Testing Power Mirror Position Sensors
    G93A01679Courtesy of Β© TOYOTA, LICENSE AGREEMENT TMS1002
  2. Using a DVOM, connect positive lead to terminal No. 6 and negative lead to terminal No. 9. Apply 12 volts to terminal No. 2 and ground terminal No. 3. See Fig 1. Observe voltmeter reading. Reverse 12-volt leads and again observe voltmeter reading.
  3. Voltage reading should be 0-0.9 volt with mirror at uppermost mirror position and 2.8-5.0 volts at lowermost position. Voltage reading should change gradually and smoothly as mirror moves.
  4. Connect positive lead of DVOM to terminal No. 4 and negative lead to terminal No. 9. Apply 12 volts to terminal No. 1 and ground terminal No. 2. Observe voltmeter reading. Reverse 12-volt leads and again observe voltmeter reading.
  5. On left mirror, voltage reading should be 2.8-5.0 volts with mirror at leftmost position and should drop to 0-0.9 volt at rightmost position. On right mirror, voltage reading should be 0-0.9 volt with mirror at leftmost position and should climb to 2.8-5.0 volts at rightmost position. If either mirror does not operate as specified, replace power mirror assembly.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.