1992 Lexus SC 400FACTORY OEM SERVICE PROCEDURE

Diode Assembly

  1. With diode (rectifier) assembly on bench, connect ohmmeter positive lead to each rectifier terminal and negative lead to positive (+) terminal. See Fig 1. Reverse ohmmeter leads and check again. Continuity should exist in one direction and not exist in the other.
  2. Connect ohmmeter positive lead to each rectifier terminal and negative lead to each negative (-) terminal. Reverse ohmmeter leads and check again. Continuity should exist in one direction and not exist in the other. If continuity is not as specified, replace diode assembly.
Fig 1: Testing Diode Assembly
G91I02734Courtesy of Β© TOYOTA, LICENSE AGREEMENT TMS1002
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.