2003 Land Rover Freelander (LN) V6-2.5LFACTORY OEM SERVICE PROCEDURE

Neutral Safety Switch: Adjustments

Inhibitor switch - adjust
Adjust
1. Set gear selector lever to 'N' position.

Factory service manual diagram




2. Loosen 2 bolts securing inhibitor switch to gearbox casing.
3. Fit tool LRT-44-018 to selector lever on gearbox, rotate inhibitor switch sufficient to insert tool alignment pin through tool lever into inhibitor switch.
4. Tighten inhibitor switch bolts to 3 Nm (2.2 ft. lbs.) and remove LRT-44-018.
5. Check that the engine will start in 'P' and 'N' positions and is inhibited when drive positions are selected.





Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.