Integrated Charging Control Unit DTCS
INTEGRATED CHARGING CONTROL UNIT DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
| DTC | Description |
|---|---|
| P0A94-00 | DC/DC Converter Performance |
| P0C3A-11 | DC/DC Converter Temperature Sensor 'A' Low |
| P0C3B-12 | DC/DC Converter Temperature Sensor 'A' High |
| P0D09-72 | Battery Charging System Positive Contactor Stuck Open |
| P0D18-12 | Battery Charging System High Voltage Interlock Circuit High |
| P0D21-16 | Battery Charger Output Voltage Too Low |
| P0D24-98 | Battery Charger Temperature Too High |
| P0D27-16 | Battery Charger Input Voltage Too Low |
| P0D28-17 | Battery Charger Input Voltage Too High |
| P0D2A-19 | Battery Charger Input Current Too High |
| P0D39-1C | Battery Charger Input Current Sensor Circuit Range/Performance |
| P0D3A-11 | Battery Charger Input Current Sensor Circuit Low |
| P0D3B-12 | Battery Charger Input Current Sensor Circuit High |
| P0D3E-1C | Battery Charger Input Voltage Sensor Circuit Range/Performance |
| P0D3F-11 | Battery Charger Input Voltage Sensor Circuit Low |
| P0D40-12 | Battery Charger Input Voltage Sensor Circuit High |
| P0D4E-11 | Battery Charger Hybrid/EV Battery Output Voltage Sensor Circuit Low |
| P0D4F-12 | Battery Charger Hybrid/EV Battery Output Voltage Sensor Circuit High |
| P0D52-1C | Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Range/Performance |
| P0D53-11 | Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Low |
| P0D54-12 | Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High |
| P0D5C-00 | Battery Charger Hybrid/EV Battery Output Power Performance |
| P0D67-00 | Battery Charger Control Module Performance |
| P0D90-38 | Battery Charger Input Frequency Incorrect |
| P1A88-98 | LDC Cooling System Fault |
| P1A89-96 | LDC Current Sensor Fault |
| P1A8A-96 | DC/DC Converter Temperature Sensor Circuit Range/Performance Fail |
| P1A8C-19 | DC/DC Converter Input Current Over Fail |
| P1A8D-13 | DC/DC Converter Voltage Path Fault |
| P1A8E-19 | DC/DC Converter Output Current Over Fail |
| P1A8F-31 | DC/DC Converter PWM Output Fail |
| P1A90-96 | DC/DC Converter Input Voltage Sensor Fault |
| P1A91-96 | DC/DC Converter Output Voltage Sensor Fault |
| P1A92-45 | LDC Control Unit Memory Error |
| P1A93-04 | LDC Control Unit Error |
| P1A96-1C | LDC Internal Power Supply Fault |
| P1A9F-00 | Internal Control Module Monitoring Performance |
| P1D1B-1C | Converter Coolant Temperature Sensor Circuit Range/Performance |
| P1D1C-11 | Converter Coolant Temperature Sensor Circuit Low |
| P1D1D-12 | Converter Coolant Temperature Sensor Circuit High |
| P1E01-1C | PFC Voltage Sensor Reliability and Initial Offset Value Check |
| P1E02-11 | PFC Voltage Sensor Circuit Low |
| P1E03-12 | PFC Voltage Sensor Circuit High |
| P1E04-1C | Battery Charger Temperature Sensor 'A' Circuit Range/Performance |
| P1E05-11 | Battery Charger Temperature Sensor 'A' Circuit Low |
| P1E06-12 | Battery Charger Temperature Sensor 'A' Circuit High |
| P1E07-1C | Battery Charger Temperature Sensor 'B' Circuit Range/Performance |
| P1E08-11 | Battery Charger Temperature Sensor 'B' Circuit Low |
| P1E09-12 | Battery Charger Temperature Sensor 'B' Circuit High |
| P1E0A-17 | Battery Charger Output Voltage Too High |
| P1E0B-19 | Battery Charger Output Current Too High |
| P1E0C-73 | Input Relay Stuck Closed Check |
| P1E0D-72 | Input Relay Open Check |
| P1E13-00 | Battery Charger Power Module System Voltage |
| P1E14-17 | PFC Output Voltage Too High |
| P1E35-17 | Battery Charger V2L Mode Unexpected AC Voltage Detected |
| P1E36-17 | Battery Charger V2L Mode DC Input Voltage Too High |
| P1E37-16 | Battery Charger V2L Mode DC Input Voltage Too Low |
| P1E38-19 | Battery Charger V2L Mode AC Output Overload |
| P1E39-00 | Battery Charger V2L Mode Output Control Performance |
| P1E40-17 | Battery Charger V2L Mode Link Voltage Too High |
| P1E50-19 | Battery Charger V2L Mode DC Input Current Exceeded BMS Limit |
| P1E51-19 | Battery Charger V2L Mode DC Input Current Too High |
| P1EFF-13 | Battery Charger AC High Voltage Interlock Circuit/Open |
| P1F33-17 | Battery Charger V2G Mode DC Input Voltage Too High |
| P1F34-16 | Battery Charger V2G Mode DC Input Voltage Too Low |
| P1F35-17 | Battery Charger V2G Mode Internal Link Voltage Too High |
| P1F37-17 | Battery Charger V2G Mode AC Output Voltage Too High |
| P1F38-16 | Battery Charger V2G Mode AC Output Voltage Too Low |
| P1F39-38 | Battery Charger V2G Mode AC Frequency Incorrect |
| P1F40-19 | Battery Charger V2G Mode AC Output Current Too High |
| P1F41-19 | Battery Charger V2G Mode DC Input Current Too High |
| P1F42-00 | Battery Charger V2G Mode Output Control Performance |
| P1F50-00 | Battery Charger V2G Mode Grid Disconnected/Islanding Operation Detected |
| U0001-88 | High Speed CAN Communication Bus |
| U0110-87 | Lost Communication With Drive Motor Control Module 'A' |
| U0111-87 | Lost Communication With Battery Energy Control Module 'A' |
| U0293-87 | Lost Communication With Hybrid/EV Powertrain Control Module |
| U130D-87 | Lost Communication with Charge Control Module (CCM) |
| U130E-87 | Lost Communication With Vehicle Charging Management System (VCMS) |
| U143A-00 | Unsupported Parameter Value Received from Bidirectional AC EVSE |
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.