2018 Kia Sedona EXFACTORY OEM SERVICE PROCEDURE

Check Generator circuit

  1. Engine starts.
  2. Maintain ENG at 2, 500 RPM over 2 minutes.
  3. Measure voltage between the battery terminal(+) and the battery terminal(-).

    Specification:  Approx. 12.5 ~ 14.7V

  4. Is the measured voltage within specification?

    YES 

    • Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage. So, check poor connections and the related circuit between PCM and component thoroughly. Repair as necessary and go to "VERIFICATION OF REPAIR " procedure.

    NO 

    • Check that the tension of drive belt, ENG RPM, fuse, terminal of battery, all terminals of generator are in good condition and Check for damaged harness and poor connection between generator and battery. If OK repair or replace generator and then go to "VERIFICATION OF REPAIR " procedure.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • • You smell fuel, burning insulation, or see smoke.
  • • Brakes feel soft, pull hard to one side, or make grinding noises.
  • • The engine overheats, stalls repeatedly, or misfires under load.
  • • You are missing required tools, torque specs, or safe lifting equipment.
  • • You are not confident in the next step or safety outcome.