2016 Kia Cadenza BaseFACTORY OEM SERVICE PROCEDURE

Electrical Circuit Inspection Procedure

  • Check Open Circuit
    1. Procedures for Open Circuit
      • Continuity Check
      • Voltage Check

        If an open circuit occurs (as seen in [Fig 1]), it can be found by performing Step 2 (Continuity Check Method) or Step Β 3 (Voltage Check Method) as shown below.

        Fig 1: Checking Open Circuit
        G11783982Courtesy of KIA MOTORS AMERICA, INC.
  • Continuity Check Method
    NOTE: When measuring for resistance, lightly shake the wire harness above and below or from side to side.

    Specification (Resistance)Β 

    1Ξ© or less β†’ Normal Circuit

    1MΞ© or Higher β†’ Open Circuit

    1. Disconnect connectors (A), (C) and measure resistance between connector (A) and (C) as shown in [Fig 2].

      In [Fig 2] the measured resistance of line 1 and 2 is higher than 1MΞ© and below 1 Ξ© respectively. Specifically the open circuit is line 1 (Line 2 is normal). To find exact break point, check sub line of line 1 as described in next step.

      Fig 2: Measuring Resistance Between Connector (A) And (C)
      G11783983Courtesy of KIA MOTORS AMERICA, INC.
    2. Disconnect connector (B), and measure for resistance between connector (C) and (B1) and between (B2) and (A) as shown in [Fig 3].

    In this case the measured resistance between connector (C) and (B1) is higher than 1MΞ© and the open circuit is between terminal 1 of connector (C) and terminal 1 of connector (B1).

    Fig 3: Measuring Resistance Between Connector (C), (B1), (B2) And (A)
    G11783984Courtesy of KIA MOTORS AMERICA, INC.
  • Voltage Check Method
    1. With each connector still connected, measure the voltage between the chassis ground and terminal 1 of each connectors (A), (B) and (C) as shown in [Fig 4].

      The measured voltage of each connector is 5V, 5V and 0V respectively. So the open circuit is between connector (C) and (B).

      Fig 4: Measuring Voltage Between Chassis Ground And Terminal 1 Of Each Connectors (A), (B) And (C)
      G11783985Courtesy of KIA MOTORS AMERICA, INC.
    • Check Short Circuit
    1. Test Method for Short to Ground Circuit
      • Continuity Check with Chassis Ground

        If short to ground circuit occurs as shown in [Fig 5], the broken point can be found by performing Step 2 (Continuity Check Method with Chassis Ground) as shown below.

        Fig 5: Checking Short Circuit
        G11783986Courtesy of KIA MOTORS AMERICA, INC.
    2. Continuity Check Method (with Chassis Ground)
      NOTE: Lightly shake the wire harness above and below, or from side to side when measuring the resistance.

      Specification (Resistance)Β 

      1Ξ© or less β†’ Short to Ground Circuit

      1MΞ© or Higher β†’ Normal Circuit

      1. Disconnect connectors (A), (C) and measure for resistance between connector (A) and Chassis Ground as shown in [Fig 6].

        The measured resistance of line 1 and 2 in this example is below 1 Ξ© and higher than 1MΞ© respectively. Specifically the short to ground circuit is line 1 (Line 2 is normal). To find exact broken point, check the sub line of line 1 as described in the following step.

        Fig 6: Measuring Resistance Between Connector (A) And Chassis Ground
        G11783987Courtesy of KIA MOTORS AMERICA, INC.
      2. Disconnect connector (B), and measure the resistance between connector (A) and chassis ground, and between (B1) and chassis ground as shown in [Fig 7].

      The measured resistance between connector (B1) and chassis ground is 1Ξ© or less. The short to ground circuit is between terminal 1 of connector (C) and terminal 1 of connector (B1).

      Fig 7: Measuring Resistance Between Connector (A) And (B1) And Chassis Ground
      G11783988Courtesy of KIA MOTORS AMERICA, INC.
      • Testing For Voltage Drop

      This test checks for voltage drop along a wire, or through a connection or switch.

      1. Connect the positive lead of a voltmeter to the end of the wire (or to the side of the connector or switch) closest to the battery.
      2. Connect the negative lead to the other end of the wire. (or the other side of the connector or switch)
      3. Operate the circuit.
      4. The voltmeter will show the difference in voltage between the two points. A difference, or drop of more than 0.1 volts (50mV in 5V circuits), may indicate a problem. Check the circuit for loose or dirty connections.
      Fig 8: Checking Voltage Drop Across Wire
      G11783989Courtesy of KIA MOTORS AMERICA, INC.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.