2004 Kia AmantiFACTORY OEM SERVICE PROCEDURE

Output Current Test: Result

  1. The ammeter reading must be higher than the limit value. If it is lower but the generator output wire is in good condition, remove the generator from the vehicle and test it. Limit value (120A generator): 84A mm
    NOTE: The nominal output current value is shown on the nameplate affixed to the generator body. The output current value changes with the electrical load and the temperature of the generator itself. Therefore, the nominal output current may not be obtained, If such is the case, keep the headlights on the cause discharge of the battery, or use the lights of another vehicle to increase the electrical load. The nominal output current may not be obtained if the temperature of the generator itself or ambient temperature is too high. In such a case, reduce the temperature before testing again.
  2. Upon completion of the output current test, lower the engine speed to idle and turn off the ignition switch.
  3. Disconnect the battery ground cable.
  4. Remove the ammeter and voltmeter and the engine tachometer.
  5. Connect the generator output wire to the generator "B" terminal.
  6. Connect the battery ground cable.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.