2004 Kia AmantiFACTORY OEM SERVICE PROCEDURE

Load Test

  1. When discharging the battery during 15 seconds at half currency of Cold Cranking Ampere (CCA), the voltage of the battery should be as shown below.
    REGULATING VOLTAGE

    Ambient Temperature Voltage
    Above 20 °C 9.6V
    ~ 18 °C 9.5V
    ~ 10 °C 9.4V
    ~ 4 °C 9.3V
    ~ -1 °C 9.1V
    ~ -7 °C 8.9V
    ~ -12°C 8.7V
  2. When the voltage is not within specification, repeat the load test again, and recharge.
  3. If the battery is left alone for 2 hours after recharging and its output is over 12.5V, and the voltage after a load test is over the standard value, the battery can be used.