2012 Jeep Grand Cherokee 2WD V8-5.7LFACTORY OEM SERVICE PROCEDURE

Blower Motor Power Module - Installation






INSTALLATION

NOTE: Automatic Temperature Control (ATC) shown. Manual Temperature Control (MTC) similar.

Factory service manual diagram




1. Position the blower motor power module (2) onto the HVAC housing (3).
2. Install the two screws (1) that secure the blower motor power module to the HVAC housing. Tighten the screws to 2 Nm (17 in. lbs.).

Factory service manual diagram




3. Connect the two wire harness connectors (1) to the blower motor power module (2).

Factory service manual diagram





NOTE: Illustration shown with instrument panel removed from view for clarity.

4. Connect the passenger side floor ducts (1) to the HVAC housing (2).
5. Install the passenger side instrument panel silencer.
6. Reconnect the negative battery cable.