2007 Jeep Commander 2WD V8-5.7L VIN 2FACTORY OEM SERVICE PROCEDURE
Control Module HVAC
Component ID: 192
Component : MODULE-FRONT BLOWER POWER
Connector:
Name : MODULE-FRONT BLOWER POWER C1
Color : BLACK
# of pins : 4
Qualifier : (ATC)
Pin Description Circuit
1 - -
2 GROUND Z134 12BK/LG
3 FRONT BLOWER CONTROL C56 20VT
4 FRONT BLOWER MOTOR RELAY OUTPUT C7 12DB
Component Location - 34
Connector:
Name : MODULE-FRONT BLOWER POWER C2
Color : BLACK
# of pins : 2
Qualifier : (ATC)
Pin Description Circuit
1 FRONT BLOWER MOTOR RELAY OUTPUT C7 12DG
2 BLOWER MOTOR GROUND C75 12BK
Component Location - 34