2000 Jaguar XJRFACTORY OEM SERVICE PROCEDURE
KICKDOWN Switch
- Ensure that the throttle cable is correctly adjusted. See THROTTLE CABLEΒ .
- Load the approved Portable Diagnostic Unit (PDU) with powertrain data logger and connect to vehicle.
- With EXISTING COMPONENTS TO BE TESTED - YES / NO displayed on the screen, select YES. Select ENTER and follow the messages given on the screen.
- Press ENTER on the PDU screen.
- Following the PDU instruction, push the throttle pedal until light contact is made with the kickdown switch and hold. Press ENTER on the display. Note the PERCENTAGE THROTTLE OPEN data (displayed as a bar graph). Release the throttle pedal.
- If the target of 90 percent throttle open specification is not achieved, the switch must be adjusted as follows:
- Pull the carpet from around the kickdown switch and disconnect the kickdown switch harness connector to avoid twisting the harness as the switch is rotated. See Fig 1 .
- Adjust the kickdown switch to 90 percent throttle open by rotating the switch in the required direction.
- Verify the setting.
- With the PDU instructions completed, connect the kickdown switch harness connector.
NOTE:
Ensure that contact with the kickdown switch does not result in switch movement.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.