1990 Jaguar XJ6 BaseFACTORY OEM SERVICE PROCEDURE

Valve Block Assembly

  1. Ensure ignition is off. Using DVOM, measure voltage between terminals No. 1 and 3 of ABS ECU connector. Turn ignition on. If voltage is more than 10 volts, valve block is okay. If voltage is less than 10 volts, go to next step.
  2. Turn ignition off. Check Red/Yellow wire between main relay terminal No. 30 and valve block terminal No. 7 for a short or open circuit. Repair wiring as necessary. If Red/Yellow wire is okay, go to next step.
  3. Check Red/Yellow wire between ABS ECU connector terminal No. 3 and valve block terminal No. 7 for a short or open circuit. Repair wiring as necessary.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.