2004 Isuzu Axiom Base, 4WDFACTORY OEM SERVICE PROCEDURE

Function Check

Use a Tech 2 to check the TP sensor output voltage at closed throttle.

  • The voltage should be TP1 about 0.4V, TP2 about 4.6V and TPS about 4.6V.
  • If the reading is abnormal value, check the throttle shaft to see if it is binding.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.