2003 Isuzu Axiom Base, RWDFACTORY OEM SERVICE PROCEDURE

Shift Lock Cable: Removal

  1. Set ignition key in "LOCK" position and selector lever in "P" position.
  2. Remove knee pads, cluster upper cover, center cluster assembly, rear console, and front console.
  3. Disconnect inner cable from selector lever assembly then push claw and disconnect cable assembly.
    Fig 1: Disconnecting Inner Cable From Selector Lever Assembly
    G02808362Courtesy of ISUZU MOTOR CO.
  4. Remove instrument panel lower cover and steering column cover.
    Fig 2: Disconnecting Lock Adjust
    G02808363Courtesy of ISUZU MOTOR CO.
  5. Remove spring pin and disconnect inner cable.
    • Disconnect outer cable from bracket.
Fig 3: Disconnecting Outer Cable From Bracket
G02808364Courtesy of ISUZU MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.