2003 Isuzu Axiom Base, RWDFACTORY OEM SERVICE PROCEDURE

Starter Specifications

STARTER SPECIFICATIONS

Application Specification
Brush
Standard .59" (15 mm)
Limit .43" (11.0 mm)
Brush Spring
Standard 39-52 Lb. (18-24 N)
Limit 26 Lb. (12 N)
Commutator Diameter
Standard 1.18" (30 mm)
Limit 1.14" (29mm)
Commutator Mica Depth
Standard .0177-.0295" (.45-.75 mm)
Limit .008" (.2 mm)
Commutator Runout
Limit .0157" (.4 mm)
Bench Testing (No Load)
Minimum Volts 11.5
Maximum Amps 90
Minimum RPM 3000
On Vehicle Testing (Under Load)
Minimum Volts 8.5
Maximum Amps 350
Minimum RPM 1000