1997 Isuzu Trooper LSFACTORY OEM SERVICE PROCEDURE

Charging System Test

  1. Disconnect harness connector from generator. Turn ignition on. Connect voltmeter between ground and harness connector terminal "L", and terminal "IG" (if used). If reading is zero, locate and repair open between terminal measured and ignition switch.
  2. Connect generator harness connector. Start engine and increase engine speed to 1500-2000 RPM, with accessories off. Using a voltmeter, measure across battery posts. If reading is greater than 16 volts, replace or repair generator. If reading is less than 16 volts, go to next step.
  3. Connect an ammeter to generator terminal "B" output terminal. Start engine and increase engine speed to 1500-2000 RPM, with accessories on. Load battery with carbon pile rheostat to obtain maximum amperes output, maintaining battery voltage at or above 13.0 volts.
  4. If output measured is within 15 amps of rated generator output, generator is okay. If output measured is not within 15 amps of rated output, repair or replace generator. Refer to the GENERATOR SPECIFICATIONSΒ  table.
GENERATOR SPECIFICATIONS

Application Rated Output (Amps)
Manual Transmission (M/T) (1) 60
Automatic Transmission (A/T) 75
(1) 75 for models equipped with optional 75-amp generator.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.