1995 Isuzu Rodeo LS, RWDFACTORY OEM SERVICE PROCEDURE

Diagnostic Circuit Check

SCAN DATA

Scan Position (1) Data Value
A/C Off (On With A/C Requested)
Battery 13.5-14.5 Volts
BLM (Block Learn Memory) 118-138 Counts
Coolant Temperature 185-221Β°F (85-105Β°C)
IAC 1-50 Counts
INT (Integrator) Varied Amount of Counts
Knock Signal No
MAP (2) 1-2 Volts
Open/Closed Loop Closed Loop (Open At Idle)
Oxygen Sensor (3) .1-.9 Volt
Oxygen Sensor Cross Counts Greater Than One
RPM 550-750 RPM
Rich/Lean Flag Varies
Torque Converter Clutch Off (On With TCC Requested)
TPS .42-.54 Volt
VSS 0 MPH
(1) With engine idling at normal operating temperature, transmission in Park or Neutral, system in closed loop and all accessories off.
(2) Voltage varies with vacuum and barometric pressure.
(3) Voltage varies with exhaust temperature.

Diagnostic circuit check will identify problem created by Electronic Engine Control System (EECS) malfunction. It is the starting point for diagnosis. This check will direct you to the next logical step in diagnosing the complaint.

After completing diagnostic circuit check and finding on-board diagnostics functioning properly with no trouble codes displayed, use appropriate SCAN DATA table for comparison.

Data values must be taken under these conditions:

  • Engine at normal operating temperature.
  • Engine running at idle.
  • Vehicle in Park or Neutral.
  • System in closed loop.

The values are an average of displayed values recorded from normal operating vehicles. Values represent what a normal functioning system would typically display.

NOTE: Only parameters supplied by manufacturer are used in this article. If a scan tester reads other parameters, values are not recommended by manufacturer for diagnostic use. A scan tester displaying faulty data should not be used, or misdiagnosis will occur. Report problem to scan tester manufacturer.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.