1995 Isuzu Rodeo LS, RWDFACTORY OEM SERVICE PROCEDURE

Code 45 - Oxygen Sensor (Rich Fuel Mixture): Notes

The ECM supplies a voltage of about .45 volt between terminals B2 and B3. Oxygen sensor varies voltage from one volt (rich exhaust) to .1 volt (lean exhaust). The sensor acts like an open circuit and produces no voltage when exhaust temperature is less than 680Β°F (360Β°C). An open sensor circuit or cold sensor causes open loop operation.

NOTE: Test number refers to number on diagnostic chart.
  1. A Code 45 is set when oxygen sensor signal voltage remains greater than .1 volt, TPS is greater than 10 percent, Codes 21A and 21B or Codes 33A and 33B are not set, engine has been running for at least 2 minutes, system is operating in closed loop, oxygen sensor voltage is less than .35 volt or greater than .55 volt, engine is at normal operating temperature, integrator mode is not at 128 counts and all conditions are present for 50 seconds.