1992 Isuzu Rodeo LS, RWD, AutomaticFACTORY OEM SERVICE PROCEDURE

Code 45 - O2 Sensor (Rich Fuel Mixture): Notes

The ECM supplies a voltage of approximately .45 volt between terminals D6 and D7. Oxygen sensor varies voltage from one volt (rich exhaust)to .1 volt (lean exhaust). The sensor acts like an open sensor circuit and produces no voltage when exhaust temperature is less than 600Β°F (316Β°C). An open sensor circuit or cold sensor causes open loop operation.

NOTE: Test number refers to test number on diagnostic chart.
  1. A Code 45 is set when oxygen sensor signal voltage or circuit No. D7 remains greater than .7 volt for 50 seconds while in closed loop, engine has been running at least one minute, and throttle angle is greater than 2 percent (about .2 volt more than idle voltage) but less than 25 percent.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.