1990 Isuzu Impulse AutomaticFACTORY OEM SERVICE PROCEDURE

Idle Air Control Valve (Impulse)

  1. If Idle Air Control (IAC) valve is operating improperly, remove IAC valve from throttle body. Inspect IAC valve and throttle body bore for signs of binding or clogged passages. Repair as necessary. If binding or clogged passages was not present, proceed to step 2).
  2. Disconnect electrical connector from IAC valve. Using ohmmeter, check resistance across terminals No. 1 and No. 2 and across terminals. No. 3 and No. 4. See Fig 1 . Replace IAC valve if resistance is not 40-80 ohms.
  3. Using ohmmeter, check continuity across terminals No. 1 and No. 4 and across terminals. No. 2 and No. 3. See Fig 1 . Replace IAC valve if continuity exists.
  4. If IAC valve tested okay, check for faulty connections at IAC valve and ECM. If connections are okay, check input devices used by ECM to control IAC valve operation.
Fig 1: Identifying IAC Valve Terminals (Impulse)
G90I17994Courtesy of ISUZU MOTOR CO.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.