1984 Isuzu Impulse AutomaticFACTORY OEM SERVICE PROCEDURE

Test 7 - Air Flow Sensor (Codes 61 And 62)

  1. Disconnect terminals at MCU and air flow sensor. Check all circuits for continuity and grounds. Repair or replace defective circuits or connections.
  2. Reconnect terminals to MCU and air flow sensor. Carefully pry open sealing gasket on the air flow sensor side of terminal connector. Connect ohmmeter to Black wire and to ground; there should be no resistance. If circuit tests good, disconnect ohmmeter. Connect voltmeter to air flow sensor under the conditions shown in chart.
    AIR FLOW SENSOR TEST CHART

    Wire Color Ignition/Engine Volts
    Red-Ground On/Not Running 10-14
    Green-Ground On/Not Running 0.2-0.6
    Green-Ground On/Running 1.0-2.0
  3. If voltage in Green wire did not increase with engine running, replace air flow sensor. If voltage was not present at Red wire, check circuits and connections.