Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
1984 Isuzu Impulse AutomaticFACTORY OEM SERVICE PROCEDURE
Test 7 - Air Flow Sensor (Codes 61 And 62)
- Disconnect terminals at MCU and air flow sensor. Check all circuits for continuity and grounds. Repair or replace defective circuits or connections.
- Reconnect terminals to MCU and air flow sensor. Carefully pry open sealing gasket on the air flow sensor side of terminal connector. Connect ohmmeter to Black wire and to ground; there should be no resistance. If circuit tests good, disconnect ohmmeter. Connect voltmeter to air flow sensor under the conditions shown in chart.AIR FLOW SENSOR TEST CHART
Wire Color Ignition/Engine Volts Red-Ground On/Not Running 10-14 Green-Ground On/Not Running 0.2-0.6 Green-Ground On/Running 1.0-2.0 - If voltage in Green wire did not increase with engine running, replace air flow sensor. If voltage was not present at Red wire, check circuits and connections.
Factory Service Tools
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.
