1984 Isuzu Impulse AutomaticFACTORY OEM SERVICE PROCEDURE

Oxygen Sensor

  1. Oxygen sensor can not be tested directly but its control signal can be checked. Circuit tester having internal resistance of approximately 20,000 ohms is necessary to test circuit.
  2. Unplug oxygen sensor harness at connector. Insert fine wire into vehicle side connector. Set tester scale to 2V and connect positive lead of tester to fine wire.
  3. With negative lead of tester to ground and plugs reconnected, start engine. Check voltage when engine speed is momentarily increased. Tester needle should deflect within range of 0-0.8V.
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.