Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
DTC Diagnosis Procedure
- CHECK FUEL PUMP RELAY POWER SUPPLYÂ
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Turn ignition switch ON.
- Check the voltage between ECM harness connector terminals.
ECM
Voltage
Connector
+
Connector
-
Terminal
Terminal
F92
93
E20
152
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK FUEL PUMP RELAY POWER SUPPLY CIRCUITÂ
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between ECM harness connector and IPDM E/R harness connector.
+
-
Continuity
ECM
IPDM E/R
Connector
Terminal
Connector
Terminal
F92
93
E13
31
Existed
- Also check harness for short to ground.
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK FPCM POWER SUPPLYÂ
- Turn ignition switch OFF.
- Reconnect ECM harness connector.
- Disconnect FPCM harness connector.
- Turn ignition switch ON.
- Check the voltage between FPCM harness connector and ground.
FPCM
Ground
Voltage
Connector
Terminal
B1
6
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- CHECK FPCM POWER SUPPLY CIRCUITÂ
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between FPCM harness connector and IPDM E/R harness connector.
+
-
Continuity
FPCM
IPDM E/R
Connector
Terminal
Connector
Terminal
B1
6
E15
54
Existed
- Also check harness for short to ground.
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK FPCM GROUND CIRCUIT FOR OPEN AND SHORTÂ
- Turn ignition switch OFF.
- Check the continuity between FPCM harness connector and ground.
FPCM
Ground
Continuity
Connector
Terminal
B1
3
Ground
Existed
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair open circuit or short to power in harness or connectors.
- CHECK FPCM INPUT AND OUTPUT CIRCUITS FOR OPEN AND SHORTÂ
- Disconnect ECM harness connector.
- Check the continuity between FPCM harness connector and ECM harness connector.
FPCM
ECM
Continuity
Connector
Terminal
Connector
Terminal
B1
4
E20
130
Existed
5
136
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 8.
NO
GO TO 7.
- DETECT MALFUNCTIONING PARTÂ
Check the following.
- Harness for open or short between FPCM and ECM
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FUEL PUMP CONTROL CIRCUIT FOR OPEN AND SHORTÂ
- Disconnect fuel level sensor unit and fuel pump harness connector.
- Check the continuity between FPCM harness connector and fuel level sensor unit and fuel pump harness connector.
FPCM
Fuel level sensor unit and fuel pump
Continuity
Connector
Terminal
Connector
Terminal
B1
1
C5
1
Existed
2
3
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 9.
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK FPCMÂ
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 10.
NO
Replace FPCM.
- CHECK INTERMITTENT INCIDENTÂ
Refer to Inspection .
INSPECTION END
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.