2017 Infiniti Q60 Base, AWDFACTORY OEM SERVICE PROCEDURE

Stop/Start System

DTC No. Detected items Stop/Start System Operating Condition In Fail Safe Mode
Idling Or Driving The Vehicle Stop/Start System Operating
Stop During Cranking
(Restart)
B1910
B1911
Sub-Battery Relay Prohibit the stop/start system operation - Prohibit the stop/start system operation from the next time
P0120 Sensor power supply Prohibit the stop/start system operation Restart the engine Prohibit the stop/start system operation from the next time
P0605 EMCM Prohibit the stop/start system operation Restart the engine Prohibit the stop/start system operation from the next time
P0607 -
P0643 Sensor power supply Prohibit the stop/start system operation Restart the engine Prohibit the stop/start system operation from the next time
P1540
P1543
P1544
Sub-Battery current sensor Prohibit the stop/start system operation - Prohibit the stop/start system operation from the next time
P1541
P1542
Restart the engine
P1546
P1547
Sub-Battery temperature sensor Prohibit the stop/start system operation Restart the engine Prohibit the stop/start system operation from the next time
P1550
P1553
P1554
Main battery current sensor Prohibit the stop/start system operation - Prohibit the stop/start system operation from the next time
P1551
P1552
Restart the engine
P1556
P1557
Main battery temperature sensor Prohibit the stop/start system operation Restart the engine Prohibit the stop/start system operation from the next time
P1575 Brake Switch Prohibit the stop/start system operation Restart the engine Prohibit the stop/start system operation from the next time
P1576
P1577
Brake pedal position Switch Prohibit the stop/start system operation Restart the engine Prohibit the stop/start system operation from the next time
P1655 Engine restart bypass Relay Prohibit the stop/start system operation Prohibit the stop/start system operation Prohibit the stop/start system operation from the next time
P1656 Engine restart bypass Relay Prohibit the stop/start system operation Prohibit the stop/start system operation Prohibit the stop/start system operation from the next time
P1805 Brake Switch Prohibit the stop/start system operation Restart the engine Prohibit the stop/start system operation from the next time
U1000 CAN communication line Prohibit the stop/start system operation Restart the engine
NOTE:

Does not start the engine by the CAN communication abnormal status

Prohibit the stop/start system operation from the next time
Factory Service Tools

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • β€’ You smell fuel, burning insulation, or see smoke.
  • β€’ Brakes feel soft, pull hard to one side, or make grinding noises.
  • β€’ The engine overheats, stalls repeatedly, or misfires under load.
  • β€’ You are missing required tools, torque specs, or safe lifting equipment.
  • β€’ You are not confident in the next step or safety outcome.

Rather have a pro handle this?

A certified mobile mechanic comes to your home or office. They bring the tools, you stay comfortable. No tow truck, no waiting room, no surprises.

Comes to youSame-day available12-month warranty
Get a Free Quote

No obligation. See pricing before you book.