Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn A/C switch and blower fan switch OFF.
- Turn ignition switch OFF.
- Check ground connection M95. Refer to Ground Inspection in
"CIRCUIT INSPECTION
".
Is the inspection result normal?Β
YES: GO TO 2.
NO: Repair or replace ground connection.
- CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Disconnect refrigerant pressure sensor harness connector.
- Turn ignition switch ON.
- Check the voltage between refrigerant pressure sensor harness connector and ground.VOLTAGE REFERENCE
Refrigerant pressure sensor Ground Voltage (V) Connector Terminal E77 3 Ground Approx. 5 Is the inspection result normal?Β
YES: GO TO Β 4.
NO: GO TO 3.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M6, E106
- Harness for open or short between ECM and refrigerant pressure sensor
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.CONTINUITY REFERENCE
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E77 1 M107 112 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?Β
YES: GO TO Β 6.
NO: GO TO 5.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M6, E106
- Harness for open or short between ECM and refrigerant pressure sensor
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.CONTINUITY REFERENCE
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E77 2 M107 105 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?Β
YES: GO TO Β 8.
NO: GO TO 7.
- Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M6, E106
- Harness for open or short between ECM and refrigerant pressure sensor
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?Β
YES: Replace refrigerant pressure sensor.
NO: Repair or replace.
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Disclosure: Verified tool recommendations may earn an affiliate commission at no cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- β’ You smell fuel, burning insulation, or see smoke.
- β’ Brakes feel soft, pull hard to one side, or make grinding noises.
- β’ The engine overheats, stalls repeatedly, or misfires under load.
- β’ You are missing required tools, torque specs, or safe lifting equipment.
- β’ You are not confident in the next step or safety outcome.